- Gas type
- H2
The H₂ Service & Commissioning Unit supports service and maintenance work on hydrogen systems. System sections operating at pressures above 60 bar can also be included in the approved service procedure following a defined pressure relief process. The permissible connection pressures for the respective process, as well as the equipment- and system-specific isolation and safety requirements, must be observed at all times.
Standard version
- Paint: blue-anthracite
Advantages & functions
Electrical data:
- Electrical conneting cable: >= 1,5 mm2 (AWG 15)
- Cable with plug 16 A
Pressure sensors:
- Measuring range: 0 - 60 bar
- Measuring range H2 sensor: 0 - 100 vol-% in nitrogen
Connection to the vehicle:
- 2x 5 m long wire braided hose DN8, connecting couplings to the vehicle, can be individually specified
- 1x 20 m long hose for connecting to a suitable exhaust air device or for venting the gas outside the workshop
Gas supply:
- 1x for nitrogen
- 1x for forming gas (5% H2 in 95% N2)
- Gases and gas cylinders are not included
Technical data
| Dimensions (W x H x D) | 735 x 1.440 x 880 mm | |
| Weight | 257 kg (empty) | |
| Sound level | < 70 dB(A) | |
| Ambient temperature | 0 to +40 °C | |
| Storage temperature | -20 to +60 °C | |
| Ambient moisture | < 90 % r. h. non-condensing | |
| Protection class | IP 44 | |
| Height | 2000 m max. above sea level | |
| Operating voltage | 230 V AC | |
| Frequency | 50/60 Hz |