The H2 filling station enables the refueling of gaseous hydrogen from up to 4 different H2 storage tanks (cylinder bundles). The filling process is simple and uncomplicated, it can be started quickly and runs automatically. Depending on the pre-pressure in the H2 storage tanks, a vehicle can be refueled up to a maximum of 300 bar.
General information:
Electrical data:
Pressure sensors:
Connection to the vehicle:
Gas supply:
| Dimensions (W x H x D) | 1,200 x 2,280 x 800 mm | |
| Weight | 250 kg | (empty) |
| Sound level | < 85 dB | |
| Ambient temperature | -20 to +40 °C | |
| Ambient moisture | < 90 % | r. h. non-condensing |
| Protection class | IP 65 | |
| Height | 2000 m | max. above sea level |
| Operating voltage | 230 V | AC |
| Frequency | 50/60 Hz | |
| Power | 10 A | max. |
| Input voltage | 380 V | max. |
| Inlet pressure | 300 bar | max. |
| Max. output pressure | 290 bar | max. |
| Pressure | 350 bar | max. |