The H2 filling station enables the refueling of gaseous hydrogen from up to 4 different H2 storage tanks (cylinder bundles). The filling process is simple and uncomplicated, it can be started quickly and runs automatically. Depending on the pre-pressure in the H2 storage tanks, a vehicle can be refueled up to a maximum of 300 bar.
Electrical data:
Pressure sensors:
Connection to the vehicle:
Gas supply:
Dimensions (W x H x D) | 1,200 x 2,280 x 800 mm | |
Weight | 250 kg | (empty) |
Sound level | < 70 dB | |
Ambient temperature | 0 to +40 °C | |
Storage temperature | -20 to +60 °C | |
Ambient moisture | < 90 % | r. h. non-condensing |
Protection class | IP 44 | |
Height | mm | max. 2000 m above sea level |
Operating voltage | 230 V | AC |
Frequency | 50/60 Hz |