The actual product may differ slightly from the image.

Alternative arc quenching and insulating gases

LeakSpy C4 for gas mixtures with C4-FN

C4-3-033-R400

Gas type
C4-FN 

For quick detection and quantifi cation of smallest leaks

The cordless battery-operated LEAKSPY C4 precisely measures the C4-FN concentration in air by means of a non-dispersive infrared sensor (NDIR sensor) and indicates the value on a graphic display in ppm. The device allows precise localisation of leaks by searching the highest C4-FN concentration.Thanks to the high resolution and detection limit, it is also possible to carry out integral measurements as well as measurements to determine the resolution and detection limit by means of this device.
To protect the device from particles the sensor is equipped with a filter which can be cleaned and/or exchanged easily by the operator. In case there is C4-FN contamination already existing, the LEAKSPY C4 can be set to this value. Thus, it is possible to detect leaks even in already contaminated areas. The C4-FN concentration is indicated in ppm as well as by an audible signal.

 

Standard version

  • shoulder belt
  • measuring sensor extension (length: 1 m)
  • transport case
  • battery charger
  • 1 accumulator
  • separate charging unit

Advantages & functions

  • detection of leaks up to 3 g / year
  • quick response time
  • no cross sensitivity to moisture and most volatile organic compounds (VOCs)
  • small, lightweight, easy to use
  • battery-operated (operating time min. 12 hours)
  • exchangeable accumulator (parallel loading of a second accumulator in separate charging unit possible)

Technical data

Dimensions (W x H x D) 125 x 142 x 280 mm 555 mm with measuring sensor
Length 300 mm Measuring sensor
Weight 1.580 kg
Power supply lithium ion batteries (operating time > 12 hours) 
Sensitivity 3 g/y C4-FN /year
Response time <1 sec T90
Storage temperature -10 to +60 °C
Detection limit 3 ppm C4-FN
Operating temperature 0 to +50 °C
Measuring principle 0 to +50  non-dispersive infrared sensor (NDIR)
Indication graphic display + acoustic signal
Resolution 1 ppm
Accuracy ≤ 50: ≤ 2  ppm
Accuracy 50 – 100: ≤ 2  ppm
Accuracy 100 – 1000: ≤ 2  % of measuring range
Indication unit ppm, g/y, cc/s
Measuring range 0 – 1,000 ppm C4-FN

Optional accessories

Shoulder belt 05-1964-R001
Learn more Add to cart
Measuring hose 3-033-R200-21
Learn more Add to cart
Sensor 3-033-R200-20
Learn more Add to cart
Particle filter 05-1177-R010
Learn more Add to cart
Transparent cap 05-1894-R001
Learn more Add to cart
Additional accumulator 05-1547-R006
Learn more Add to cart
Carrier case (for replacement) without foam lining   05-1522-R008
Learn more Add to cart
Foam lining for carrier case 05-0898-R014
Learn more Add to cart